Fertilizer Academy has developed CASTU13, Explosion Inside a High-Pressure Urea Reactor – Case Study, to help operators and technical specialists learn from a documented high-pressure reactor incident.
A warning during startup
During startup of a urea plant, personnel heard rumbling and observed vibration. The operating team checked the plant, but no significant deviation in the process parameters was identified. The plant then continued to run normally.
The true extent of the event was discovered only during a later turnaround. All 14 reactor trays had been displaced and were piled at the bottom of the reactor. Many trays were heavily deformed, yet the reactor pressure boundary had remained intact.
What the damage revealed
The upper three trays were bent upward, while the fourth and lower trays were bent downward. This opposite deformation pattern indicated that the pressure source was most likely located between the third and fourth trays, above the liquid level.
The documented analysis concluded that a deflagration was the most likely explanation. The event was assessed as having occurred during startup at approximately 20-50 barg. The calculated pressure surge was 71-179 barg, below the reactor design pressure of 250 barg. There was no loss of containment, but the analysis showed that the consequences could have been catastrophic if a similar event had occurred at a higher operating pressure.
How an explosive mixture could form
The carbon-dioxide feed contained more hydrogen than usual. As ammonia and carbon dioxide condensed during pressurisation, the relative concentration of hydrogen and other inerts increased in the gas phase. Oxygen was also present for reactor passivation. Under these transient conditions, the gas composition could enter the explosive range.
Pressure and hydrogen both reduced the temperature required for ignition. Reactor trays could remain above 200 degrees Celsius because of thermo-compression and steam condensation. Auto-ignition on a hot tray or a static discharge were therefore considered credible ignition mechanisms.
Actions taken after the incident
- A hydrogen analyser was introduced on the carbon-dioxide feed.
- Startup and shutdown procedures were revised so the reactor outlet and vent were not fully closed and accumulated inerts could pass downstream.
- Operators received additional training on transient hazards and warning signs.
- The safety analysis was expanded to include startup and shutdown conditions, not only normal operation.
Who should take this course
The course is intended for operators, process engineers, maintenance specialists and process-safety teams working with urea synthesis and high-pressure equipment. It is also useful to engineering contractors, equipment manufacturers, technology providers, inspection companies and specialist vendors whose work relates to reactor internals, gas analysis, high-pressure equipment or transient-risk management.
Use it in a focused skills package
CASTU13 can be taken as a standalone course or included in the Urea Incidents & Lessons Learned package. Companies can also combine it with other courses through Build Your Own Training Package to create focused learning for operators and engineers without following a fixed training pathway.
Collaboration with engineering companies and providers
Because this case touches high-pressure equipment, reactor internals, hydrogen monitoring, inspection and process safety, it can also support technical dialogue with engineering organisations and solution providers. Through the Fertilizer Academy Industry Ecosystem, equipment manufacturers, technology providers, specialist vendors and engineering companies can propose verified supplementary commentary, an equipment-specific perspective or a connected incident story for educational use.
Educational reconstruction
This is a widely discussed industry case. Fertilizer Academy presents it as an independent educational reconstruction based on available technical and training information. It is not an official incident investigation and does not replace plant-specific procedures, formal safety analysis or professional engineering judgement. Where suitable verified material is available, the learning story may be complemented by additional technical perspectives or a related case.
Links
Full course: https://fertilizer.academy/courses/explosion-inside-a-high-pressure-urea-reactor-case-study/
Incidents and Case Studies: https://fertilizer.academy/course-category/incidents-case-studies/
Partnership and collaboration: https://fertilizer.academy/industry-ecosystem/
Skills packages: https://fertilizer.academy/skills-packages/
Enterprise training: https://fertilizer.academy/enterprise-contact-form/
Fertilizer Academy: https://fertilizer.academy/
Developed by the Fertilizer Academy Team.